Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add filters








Language
Year range
1.
Acta Academiae Medicinae Sinicae ; (6): 787-792, 2019.
Article in Chinese | WPRIM | ID: wpr-781660

ABSTRACT

To summarize and analyze the causes of hyponatremia in patients with brucellosis and explore the clinical manifestations of syndrome of inappropriate antidiuresis(SIAD)in patients with brucellosis. The clinical data of 111 patients with acute brucellosis who were treated in Peking Union Medical College Hospital from September 2011 to December 2017 were retrospectively reviewed.Hyponatremia was defined by serum sodium level lower than 135 mmol/L.Clinical characteristics including medical histories,vital signs,and laboratory test findings were collected and analyzed. Hyponatremia was found in 14(12.6%)of 111 patients with brucellosis,among whom 3 patients were confirmed to be with SIAD,10 were suspected as SIAD,and 1 was diagnosis as hypopituitarism.Hypoalbuminemia,elevation of erythrocyte sedimentation rate,and high sensitivity C reactive protein were found in brucellosis patients with SIAD,along with severe complications such as infective endocarditis,septic shock,and anemia. Hyponatremia is not a rare condition in brucellosis patients and may be caused by SIAD.


Subject(s)
Humans , Brucellosis , Hyponatremia , Inappropriate ADH Syndrome , Retrospective Studies
2.
Journal of Modern Laboratory Medicine ; (4): 95-98, 2018.
Article in Chinese | WPRIM | ID: wpr-696172

ABSTRACT

Objective To explore the new clinical significance of these routine test indexes and find the early biomarkers for predicting hypertension disorder complicating pregnancy(HDP) by the comparative analysis between pregnant women with HDP and normal pregnant women before 20 weeks,including biochemical,blood coagulation and blood routine indexes.Methods A case-control study was conducted to review the clinical data of pregnant women who were undertaken prenatal examination and delivered in Guangzhou Women and Children's Medical Center from 2012 to 2016.The pregnancy were divided into HDP group and control group according to the gestational week and age.Analyzed the related test indexes before 20 weeks of pregnancy.The two groups variables were analyzed by Kolmogorov-Smirnov for normal distribution.Approximate measurement data of normal distribution were mean± standard deviation (x± s) for statistical description,while the data of the skewed distribution was median and percentile[M(P25~P75)]for statistical description.The diagnostic value was analyzed by logistic regression equation and receiver operating characteristic curves (ROC).Results The level of biochemical indexes (AST,γ GT and UA) of HDP group was significantly higher thanthe normal group (t=2.50,3.34,4.56,P< 0.05).Meanwhile the level of blood indexes (RBC,PLT and HCT) of HDP group was significantly higher than the normal group (t=2.89,4.51,3.29,all P<0.01).Other indicators of two groups (ALT,TBIL,Cr,Urea,PT,APTT,TT,FIB and HGB) were not significantly different (t=0.25~ 1.85,all P>0.05).Then the logistic regression model equation was Y=-5.497+0.010 * PLT+0.043 * γ-GT+0.007 * UA+0.045 * AST.The area under ROC curve (AUC) was 0.746 for the combination of the four indexes.The combination resulted in a higher sensitivity of 0.818 and specificity of 0.523.Conclusion Before 20 weeks of gestation,compared with normal group,liver and kidney function in patients with HDP and high blood coagulation state was damaged.Can by combined detection of AST,UA,γ-GT and PLT index,early prevention and diagnosis of gestational hypertension,effective intervention measures taken as soon as possible to improve the prognosis of pregnancy.

3.
Chinese Medical Equipment Journal ; (6): 78-81,85, 2017.
Article in Chinese | WPRIM | ID: wpr-662521

ABSTRACT

Objective To evaluate the reliability of HARSHAW-3500 thermoluminescence dosimetry system by testing its performances.Methods HARSHAW-3500 thermoluminescence dosimetry system had its performances tested and evaluated according to Verification regulation of thermoluminescence dosimetry systems used in persontal and environmental monitoring forXandgammaradiation(JJG 593-2006),Testingcriteriaofpersonneldosimetryperformanceforexternalexposure (GBZ 207-2016),Specifications for individual monitoring of occupational external exposure (GBZ 128-2016) and Thermoluminescence dosimetry systems for personal and environmental monitoring (GB/T 10264-2014),such as batch homogeneity,repeatability,linearity,incidence angle response,stability,energy response and scale factor,quantity inspection,residual dose,detection limit and etc.Results Testing results of various performance indicators proved to be within the limits according to national and industrial standards.Conclusion HARSHAW-3500 thermoluminescence dosimetry system conforms to the requirements for radiation dose measurement.It is beneficial to the improvement of quality and performance of thermoluminescence dosimetry by performances analysis and evaluation.

4.
Chinese Medical Equipment Journal ; (6): 78-81,85, 2017.
Article in Chinese | WPRIM | ID: wpr-660207

ABSTRACT

Objective To evaluate the reliability of HARSHAW-3500 thermoluminescence dosimetry system by testing its performances.Methods HARSHAW-3500 thermoluminescence dosimetry system had its performances tested and evaluated according to Verification regulation of thermoluminescence dosimetry systems used in persontal and environmental monitoring forXandgammaradiation(JJG 593-2006),Testingcriteriaofpersonneldosimetryperformanceforexternalexposure (GBZ 207-2016),Specifications for individual monitoring of occupational external exposure (GBZ 128-2016) and Thermoluminescence dosimetry systems for personal and environmental monitoring (GB/T 10264-2014),such as batch homogeneity,repeatability,linearity,incidence angle response,stability,energy response and scale factor,quantity inspection,residual dose,detection limit and etc.Results Testing results of various performance indicators proved to be within the limits according to national and industrial standards.Conclusion HARSHAW-3500 thermoluminescence dosimetry system conforms to the requirements for radiation dose measurement.It is beneficial to the improvement of quality and performance of thermoluminescence dosimetry by performances analysis and evaluation.

SELECTION OF CITATIONS
SEARCH DETAIL